Thermal Current Rating | 100A | 125A |
Intermittent Current Rating: | ||
30% Duty | 185A | 230A |
40% Duty | 160A | 200A |
50% Duty | 140A | 175A |
60% Duty | 130A | 160A |
70% Duty | 120A | 150A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
Blowouts | 600A at 96V D.C. | |
No Blowouts | 600A at 48V D.C. | |
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) | ||
Blowouts | 190A at 96V D.C. | |
No Blowouts | 190A at 60V D.C. | |
Maximum Recommended Contact Voltages | ||
Blowouts | 96V | 96V |
No Blowouts | 48V | 60V |
Typical Voltage Drop per pole across New Contacts at 100A | 40mV | |
Mechanical Durability | > 5,000,000 Cycles | |
Coil Voltage Available (Us) (Rectifier board required for A.C.) | 6 - 240V |